EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Reset (R)

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1772 HEIDENHAIN Technical Manual iTNC 530 HSCI
9.8.15 RESET (R)
Syntax: R (RESET)
Operands: M, I, O, T, C
Action:
If the logic accumulator = 1, then set the addressed operand to 0, otherwise
do not change it. Use the R command at the end of a sequence of logical
gating operations in order to influence an operand, depending on the result of
gating. This command can be used several times in succession (see example).
Example:
Gate input I4 and I5 with OR. If the gating result is 1, then reset output O2 and
marker M500.
Initial state:
Input I4 = 1
Input I5 = 0
Output O2 = ?
Marker M500 = ?
Function STL Accumulator
content
Operand content
Load the operand content
into the logic
accumulator.
L I4 1 1
Gate the content of the
logic accumulator and
input I5 with OR.
O I5 1 0
Since the result of the
operation is 1, reset
output O2.
R O2 1 0
Since the result of the
operation is 1, reset
marker M500.
R M500 1 0

Table of Contents

Other manuals for HEIDENHAIN iTNC 530 HSCI