July 2013 8.1 Display and operation 1161
Erasing the status
information
To erase the status information, tool data and contents of the Q parameters:
Select the conditions with MP7300.
Status information is all programmed values, such as scaling factor, datum
shift, feed rate, tolerance from Cycle 32, etc. These are all reset, and the
tolerance programmed in Cycle 32 is erased (is only effective again with
MP1096.x). The Q parameters and tool data are set to zero.
MP7300 Erasing the status information, tool data and Q parameters
Input: 0: Erase the status information, Q parameters and tool data if a
program is selected.
1: Erase the status information, Q parameters and tool data if a
program is selected and in the event of M02, M30, and END
PGM.
2: Erase the status information and tool data if a program is
selected.
3: Erase the status information and tool data if a program is
selected and in the event of M02, M30, END PGM.
4: Erase the status information and Q parameters if a program
is selected.
5: Erase the status information and Q parameters if a program
is selected and in the event of M02, M30, END PGM.
6: Erase the status information if a program is selected.
7: Erase the status information if a program is selected and in
the event of M02, M30, END PGM.
Input Erase with
PGM MGT
Erase with
M02, M30,
END PGM
Status
information
Tool
data
Q
parameters
0x x x x
1x x x x x
2x x x
3x x x x
4x x x
5x x x x
6x x
7x x x