July 2013 4.4 List of machine parameters 535
4.4.9 3-D touch probe
MP Function and input Software
version and
behavior
Page
MP6010 Selection of the touch probe
Input: 0: Touch probe with cable transmission (TS 120,
TS 220)
1: Touch probe with infrared transmission (TS 632)
2: Touch probe with infrared transmission (TS 440, TS 640)
3: Battery-free TS 444 touch probe
PLC
CN123
1535
MP6120 Probing feed rate (triggering touch probe)
Input: 1 to 10 000 [mm/min]
PLC
RUN
CN123
1540
MP6130 Maximum measuring range
Input: 0.001 to 99 999.9999 [mm]
PLC
RUN
CN123
1540
MP6140 Setup clearance above measuring point
Input: 0.001 to 99 999.9999 [mm]
PLC
RUN
CN123
1540
MP6150 Rapid traverse in probing cycle
Input: 10 to 20 000 [mm/min]
PLC
RUN
CN123
1540
MP6151 Pre-positioning in probing cycle with rapid traverse
Input: 0: Pre-position with speed from MP6150
1: Pre-positioning at rapid traverse
PLC
RUN
CN123
1539
MP6160 M function for probing from opposite orientations
Input: –1: Spindle orientation directly by NC
0: Function inactive
1 to 999: Number of the M function for spindle orientation
by the PLC
PLC
RUN
CN123
1544
MP6161 M function for orienting the touch probe before every
measuring process
Input: –1: Spindle orientation directly by the NC
0: Function inactive
1 to 999: Number of the M function
PLC
RUN
CN123
1542
MP6162 Orientation angle
Input: 0 to 359.9999 [°]
PLC
RUN
CN123
1542
MP6163 Minimum difference between the current spindle angle and
MP6162 before executing an oriented spindle stop
Input: 0 to 3.0000 [°]
PLC
RUN
CN123
1542