July 2013 3.8 Supply voltages in the HSCI system 229
3.8.2 Current consumption of the HSCI components
The following table shows the current consumption of the HSCI components
at 24-V NC:
HSCI component Current consumption
at 24 V DC
MC 6240 / 6241 /
MC 6242
1.7 A
MC 6341 1.8 A
MC 6222, MC 7222 2.5 A
Machine operating
panel
PLB 6001 0.2 A (without
handwheel)
MB 6xx / MB 7xx 0.2 A (without
handwheel)
Keyboard unit TE 6xx / TE 7xx 0.2 A (without
handwheel)
PLC inputs/outputs PLB 62xx 0.3 A (without touch
probe)
PLB 61xx 0.2 A
PLD 0.05 A
PLA 0.1 A
Visual display unit BF 760 2.5 A
BF 260 2.5 A
BF 750 2.1 A
BF 250 2.1 A
Handwheels HR 410 0.05 A
HR 520 0.05 A
HRA 551FS + HR
550FS
0.5 A (during charging)
HR 130 0.05 A
HR 110 + 3 x HR 150 0.2 A
Touch probes See specifications of the touch probes