EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Module 9094 Write Data into a Tool and Datum Table

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1576 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9094 Write data into a tool and datum table
Prerequisite for table: M status must be set.
You transfer the line number and the element number of the element to be
overwritten.
The value is given as a natural number, shifted by the number of decimal
places that can be entered.
The execution of Module 9094 reinitializes the geometry.
The module must be called in a submit job or spawn job.
Call:
PS B/W/D/K <File type (see Module 9092)>
PS B/W/D/K <Line number>
PS B/W/D/K <Element number (see Module 9092)>
PS B/W/D/K <Element value>
CM 9094
PL B/W/D <Error number>
0: No error. Element was written.
1: Call was not in a submit or spawn job
2: File type does not exist
3: No file of the entered type was found with M status
4: Line number not in file
5: Incorrect element number
6: Element value is outside the permissible range
Error code:
Marker Value Meaning
M4203 0 No errors
1 See above for errors