July 2013 6.14 Commissioning 1023
6.14.4 Commissioning digital control loops with TNCopt
In order to commission digital control loops with TNCopt, you must carry out
preparations on the control as described in this chapter. Also pay attention to
the notes in the documentation for TNCopt. Functions not supported by
TNCopt must be commissioned manually (see "Commissioning of digital axes"
on page 1026 and see "Commissioning the digital spindle" on page 1055).
The PC software TNCopt will also be in continuous development. You will find
a description of this software and a function overview in the help files of the
software.
When commissioning with TNCopt, the machine axes must be moved. For
safety purposes, a function of this type should be enabled on the control. The
entry TNCOPT.LOCKSOFTKEYVISIBLE = YES in OEM.SYS makes the soft key
TNCOPT OFF ON visible after pressing the MOD key. It is used to enable such
functions. As a default, the soft key is always set to OFF when the control is
started up.
Current controller
Switch on the control.
Do not acknowledge the Power Interrupted message. In the Programming
and Editing mode of operation, use the MOD key to enter the code number
688379 or 807667 (followed by the DIAGNOSIS and DRIVE DIAGNOSTICS
soft keys) to switch to the Drive Diagnostics mode of operation.
Press the I CONTROL soft key.
Acknowledge the Power Interrupted message in the Manual mode of
operation.
Switch on the control voltage.
Switch to the Oscilloscope mode of operation.
Press the START STEP soft key.
Commission the current controller with TNCopt.