1296 HEIDENHAIN Technical Manual iTNC 530 HSCI
Additional log A second log is automatically created parallel to the standard log. It is in the
battery-buffered RAM, and so enables access to the log data on the control
even without a hard disk. Enter the code number LOGBOOK1 to output it and
save it as an ASCII file, just as the standard log.
This log is not available for the programming station.
Module 9275 Write ASCII data into the log
With Module 9275 you can write ASCII data into the log. For later editing the
entry can be given an identifier.
Call:
PS B/W/D/K/S<Log entry>
–1: No entry
PS B/W/D/K/S<Log identifier>
–1: No entry
PS B/W/D/K <Priority>
0: Information
1: Warning
2: Error
CM 9275
Error code:
Marker Value Meaning
M4203 0 Entry was written
1 Error code in W1022
W1022 1 Invalid priority
2 Invalid string number or invalid immediate string
12 No string end identifier
20 Module was not called in a spawn or submit job