480 HEIDENHAIN Technical Manual iTNC 530 HSCI
4.3.2 Activating the machine parameter list
After you have entered all the values for the machine parameters:
Exit the machine parameter list by pressing the END key.
Missing or incorrect entries result in error messages from the control that
prompt you to correct your entry. The following errors are displayed:
If the control does not recognize any errors, it automatically exits the machine
parameter editor and is ready for operation.
If you do not make any entries in the machine parameter list during initial
commissioning and exit the editor with the END key, the iTNC generates a
standard machine parameter list (MP NAME). In this list the iTNC is defined as
a programming station with the HEIDENHAIN standard colors. In all other
machine parameters a default value is entered.
You can enter more than one machine parameter list in the iTNC:
Select the lists with the PGM MGT key and the SELECT soft key. The last
selected machine parameter list becomes active when you exit the machine
parameter editor.
4.3.3 Changing the input values
A machine parameter list can be changed either with the machine parameter
editor or directly through the PLC. The "List of Machine Parameters" includes
the following symbols:
Input error Meaning
0 No MP number found
1 Invalid MP number
2 No separator (:) found
3 Input value incorrect
4 MP defined twice
6 MP cannot be saved
Indicator Change by / Reaction
CN123 The MP is also accessible through the code number 123.
PLC The MP can be changed via the PLC; it can also be
changed in a running NC program during a strobe output.
RUN The MP can also be changed while an NC program is
running.
RESET Changing the MP results in a reset.
REF The axis must be moved over the reference mark again.

Table of Contents