1934 HEIDENHAIN Technical Manual iTNC 530 HSCI
Network settings In the standard version, the Ethernet interface X26 of the IPC 6341 is
configured for DHCP. The second Ethernet interface is configured with a fixed
IP address (198.168.254.3).
HEIDENHAIN recommends the following configuration for the connection of
the IPC 6341:
To use the recommended configuration with the IPC 6341, configure the
Ethernet interface "eth1/X116" of the NC main computer with the
"MachineNet" profile that is already saved, and activate it. This gives the NC
main computer the IP address 198.168.254.2.
Machine network
MC 6xxx
198.168.254.2
IPC 6341
198.168.254.3
Optional
switch
Company network
X116
X116
X26
X26
DHCP
DHCP

Table of Contents