EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Module 9090 Select a Line in the Pallet Table

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2013 8.7 Pallet management 1497
Module 9090 Select a line in the pallet table
With this module, you set the cursor on a particular line of the pallet table that
you selected in the program run mode. If the iTNC is in another mode, the
selection will be made when the control returns to the Program Run, Single
Block or Program Run, Full Sequence operating mode.
The selection is possible only as long as no pallet file has been started.
Call only in a submit job or spawn job.
Call:
PS B/W/D/K <Line number in the pallet table>
CM 9090
PL B/W/D <Error code>
0: No error, line was selected
1: Module was not called in a spawn or submit job
2: Call during a running NC program
3: No pallet table selected in full sequence
4: Line does not exist
Error code:
Marker Value Meaning
M4203 0 No error
1 Error code in W1022
W1022 1 Line does not exist
20 Module was not called in a spawn or submit job
21 Call during a running NC program
56 No pallet table selected in Full Sequence