July 2013 8.1 Display and operation 1169
Error code:
8.1.3 Operating times
The iTNC can measure up to 16 operating times and store them in a file in the
SYS partition:
For all operating modes except Programming and Editing and Test Run:
Press the MOD key and press the MACHINE TIME soft key.
With MP7237.x, specify the times that can be reset with the code number
857282, and the PLC operating times that you wish to display.
In MP7238.x, define the dialog messages to be displayed for the individual
operating times.
The time is measured in seconds and is updated every minute during the run
time. When the control is switched off, no more than one minute is lost.
Marker Value Meaning
M4203 0 Function performed
1 Error code in W1022
W1022 1 Invalid group number
2 Invalid value for bit mask
20 Module was not called in a spawn job or submit job
Operating time Meaning
TNCTIME Control on
MACHINETIME Machine on
PROGTIME Program run
PLCTIME0 to PLCTIME12 Definable times of the PLC