HEIDENHAIN iTNC 530 HSCI - Display;Delete PLC Soft-Key Row; Soft-Key Rows

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2013 8.3 PLC soft keys 1389
8.3.3 Soft-key rows
With Module 9200 you can display entire soft-key rows. With Module 9201
you can show individual soft keys. With Module 9202 you can switch to the
display with PLC soft keys and PLC windows.
Display/delete PLC
soft-key row
In the system file PLC:\PLCSOFTK.SYS, enter the names and path of the
required soft-key files. With the sequence of your entries you specify the
soft-key number: Line 0 = soft-key number 0, etc. One soft-key level can
consist of up to four soft-key rows, i.e. 32 soft keys per level.
When calling the module, indicate the row to be displayed first.
With the transfer parameter, specify how the soft keys should be displayed:
After the screen management key is pressed, i.e. after the PLC window
is selected.
In the current operating mode:
In this case the NC soft keys are overwritten.
Specify whether the NC soft keys should be overwritten or whether the PLC
soft keys should be appended to the NC soft keys. If you append the PLC
soft keys, a separate list is opened. Only one PLC soft-key row can be
appended.
Set Reset
W302 Number of the horizontal PLC soft
key that was pressed
NC NC