1530 HEIDENHAIN Technical Manual iTNC 530 HSCI
8.10 Incremental jog positioning
The "incremental jog positioning" function is switched on and off with the
INCREMENT OFF/ON soft key.
To position with incremental jog, press the direction keys (W1046/W1144/
W1048/W1148).
You can interrogate the current state with Marker M4579.
You can limit the jog increment with Module 9036.
You can ascertain the current jog increment with Module 9035.
You can switch the incremental jog function on and off through the PLC with
Module 9186.
Module 9036 Write status information
The information to be overwritten is designated with a transferred number.
Call:
PS B/W/D/K <Number of the status information>
PS B/W7D/K <Value to be written>
CM 9036
PL B/W/D <Error code>
0: Status written
1: Incorrect status code
2: Transferred value is out of input range
3: Input disabled
Set Reset
M4579 INCREMENT OFF/ON soft key NC NC
Number of the
status information
Function Value
0 to 7 See
"Handwheel"
10 Jog increment
limiting
0.0001 to 10 mm:
Jog increment limiting
–1; < –2; > 50:
Cancellation of jog increment
limitation and activation of the jog
increment entered last
–2:
Cancellation of the jog increment
limitation and activation of the
minimum from the jog increment
entered last and the last limitation
11 to 19 See
"Handwheel"