EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Module 9205 Set the Word for Acknowledgment of PLC Soft Keys

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1382 HEIDENHAIN Technical Manual iTNC 530 HSCI
Module 9205 Set the word for acknowledgment of PLC soft keys
Module 9205 can be used to define another word, in addition to W302/W304,
in which the pressing of PLC soft keys is acknowledged. This can be done for
the complete project file, individual PLC soft-key menus or individual PLC soft
keys. Changes in individual PLC soft keys affect the entire project file.
Call:
PS D <Resource handle>
Resource handle from Module 9203
PS B/W/D/K <Mode>
0: Complete project file
1: Individual menu
2: Individual PLC soft key
PS B/W/D/K <Number of PLC soft-key menu/Number of PLC soft key>
If "complete project file": Non-functional, transfer 0
PS D <Reserved>
0 transferred
PS B/W/D/K <PLC word address for PLC soft keys>
–1: W304
CM 9205
Error code:
Marker Value Meaning
M4203 0 No error
1 Error code in W1022
W1022 1 Invalid PLC word address
2 Incorrect resource handle or incorrect mode
3 Invalid PLC label address
20 Module was not called in a spawn or submit job
44 Error during setting of setup parameters