July 2013 8.1 Display and operation 1289
Standard log The standard log serves as a troubleshooting aid. There are 4 MB of memory 
available for this purpose.
All entries in the log are marked with the momentary date and time.
You can read out the standard log in two ways:
 After entering the code word LOGBOOK, enter the path and name of an 
ASCII file and the time and date from which the log should record, as well 
as the time and date up to which it should record. After that, an ASCII file is 
generated and opened with the log entries.
 The PC software programs PLCdesign, TNCremo, and TNCremoNT offer 
you several functions for reading out the log.
Entry Description
RESET Powering up the control
BERR Blinking error message
BREG Register contents with a blinking error message
ERR Error messages
 P: PLC error message with the line number in the 
PLC error text file
 N: NC error message with number
 Power fail interrupt: Control was switched off by 
a POWERFAIL
 Result of the file system test (in case the control 
was not properly shut down previously)
ERR dosfsck -a  Check of the PLC: and TNC: hard-disk partitions if the 
control was not shut down correctly
INFO "xxx" "xxx": Name of the control process that enters the 
information in the log
 PLC
 SYS
 MAIN
 REMO
 CTRL
 SMARTNC
 SMARTNC_LDF
 BDEHAN
 SOKY
 GEO
 PYTHON
 FIXTURE
 FILEMAN
INFO CTRL KINEMATIC Active tool with tool number, radius (R =) and length 
(L =)
INFO CTRL collision Status of collision monitoring in the Manual and 
Automatic operating modes
INFO CTRL REG 
AXIS xx START REF=yy
Position yyyy of axis xx at start of movement