1674 HEIDENHAIN Technical Manual iTNC 530 HSCI
9.1.5 The I/O-FORCE LIST
With the I/O-Force List you create a table in which the status of selected
inputs and outputs is written based on the process image.
Meaning of the columns in I/O-FORCE LIST:
SYMBOL: Symbolic address of the operand
ADDR: Absolute address of the operand
VALUE: Content of the operand
COMMENT: Comment for the operand
Add operands
to I/O -FORCE LIST
Press the WATCH LIST or TABLE soft key in the PLC Programming operating
mode.
With WATCH LIST: In the WATCH LIST, select the line with the desired
operand (input or output). You may also select the operand via the SYMBOL
LIST first.
With TABLE: In the TABLE, select the desired operand via soft key and the
keyboard arrow keys.
Press the ADD TO I/O-FORCE LIST soft key.
The operand is written to the I/O-FORCE LIST, and a message confirming the
transfer of the operand to the I/O-FORCE LIST appears.
Danger
The I/O-FORCE LIST can overrule safety-relevant monitoring operations as
well as any inputs and outputs in the PLC program! Activation of the I/O-
FORCE LIST can therefore only be done with extreme care. Also make sure
that hanging axes are supported.
Note
When using the I/O-FORCE LIST, remember that:
If an operand is entered and the I/O-FORCE LIST is activated via soft key,
then this operand is marked in color in the TABLE, and the SET and RESET
soft keys have no meaning.
The green error message I/O-Force is output in the PLC Programming
mode of operation if the I/O-FORCE LIST is active.