EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Page 1417

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
July 2013 8.5 Files 1417
Module 9250 Start the PLC editor for tables
With this module you start a table editor in the machining modes (compare
"Tool Tables").
Call only in a submit job or spawn job.
Call:
PS B/W/D/K/S<String with table name>
Complete path and name
PS B/W/D/K/S<String with columns to be edited>
PS B/W/D/K <First line >
[0 to 65 535]
PS B/W/D/K <Last line>
[0 to 65 535]
PS B/W/D/K <Mode>
Bit 0=1: Lines can be inserted and deleted
(if all lines and columns are selected)
Bit 1=1: Edit in the original file
(if all lines and columns are selected)
Bit 2=0: Shown as a table
Bit 2=1: Shown as a form
Bit 3=1: Write-protection of the file to be opened is
respected
CM 9250
Error code:
Marker Value Meaning
M4203 0 Editor was opened
1 Error code in W1022
W1022 1 First and last line do not define a meaningful range, or
incorrect value for mode was transferred
3 Impermissible string number
6 Write-protected file cannot be opened if write-
protection is active (bit 3 = 1)
7 The module could not read from the table or open the
temporary file
8 The module was called from an operating mode in
which the table editor cannot be started.
20 Module was not called in a spawn job or submit job
28 PLC editor already open for another table
29 The opened file is not a table (extension .TAB or .P)
30 Column name not found
36 Invalid file name or file type programmed
Set Reset
M4159 PLC editor: END key or soft key
pressed
NC NC/PLC

Table of Contents