1010 HEIDENHAIN Technical Manual iTNC 530 HSCI
Counting direction of the motor encoder (DIRECT.)
Maximum temperature (T-MAX) in °C
Maximum current (I-MAX) in A
Rated power output (P-N) in W
Motor mass moment of inertia (J) in kgm
2
Inductance of the series reactor (L) in µH
Thermal time constant for direct current (T-DC) in seconds
Lower thermal limit frequency (F-DC) in Hz
Thermal time constant for alternating current (T-AC) in seconds
Upper thermal limit frequency (F-AC) in Hz; above this frequency, the
maximum current I-MAX applies
Thermal time constant for winding (Tth1) in s
Thermal resistance between winding and lamination (Rth1) in K/W
Thermal time constant for lamination (Tth2) in s
Thermal resistance between lamination and coolant (Rth2) in K/W
Stall torque (M0) in [Nm]
The entry is currently not yet evaluated, however.
Torque (Mmax) at Imax in [Nm]
The entry is currently not yet evaluated, however.
Direct inductance (Ld) in [mH]
The entry is currently not yet evaluated, however.
Quadrature inductance (Ld) in [mH]
The entry is currently not yet evaluated, however.
Recommended PWM frequency of the motor (Fpwm) in [Hz]
The entry is currently not yet evaluated, however.
Current controller factor (Kp) in [V/A] calculated from the motor data
The entry is currently not yet evaluated, however.
Current controller factor (Ki) in [V/A/s] calculated from the motor data
The entry is currently not yet evaluated, however.
Type of temperature sensor (TempSens)
The entry is currently not yet evaluated, however.
Iron loss resistance [Rfe] in [ohms]
The entry is currently not yet evaluated, however.