July 2013 7.4 Single-speed, double-speed, PWM frequency 1081
Figure 2: Impermissible parameterization
HEIDENHAIN recommends using the MS 11x installation kits for a multi-row
configuration with several UV(R) supply modules, see page 122.
All UV(R) power supply modules must be connected to the grounding
conductor with a cross section of at least 10 mm2.
The signal-ground connections of the CC 61xx should always be connected
to the housing if only one CC 61xx per row is used.
If one or more than one UP is used, the UPs must always be connected to
the DC-link of the respective inverter. HEIDENHAIN recommends
connecting the UPs to the left of the CC 61xx.