July 2013 8.1 Display and operation 1227
Example of an AFC.TAB:
Proceed as follows to create the AFC.TAB file (only necessary if the file does
not yet exist):
Select the Programming and Editing operating mode.
Select the file manager: Press the PGM MGT key
Select the TNC:\ directory.
Create the new AFC.TAB file and confirm with the ENT key. The TNC displays
a list with table formats.
Select the AFC.TAB table format and confirm with the ENT key. The TNC
creates the table with the Standard control strategy.
PLC The value entered here is written to word W342 at the
beginning of a cut. Word W342 can be evaluated in a PLC
program. Depending on this, any necessary fine adjustments to
the adaptive feed control can be performed from the PLC
program. Maximum input range: 3 digits.
NR AFC FMIN FMAX FIDL FENT OVLD POUT SENS PLC
0 Standard 70 125 100 80 - 5 100 0
Column Function