July 2013 8.1 Display and operation 1259
Explanation of the columns in the table MFUNCT.TAB:
Column name Description Input
NR Number of the M function –
MACRO Is the macro present? YES:
"Y", "y" or "1"
NO:
"N", "n" or "0"
EFFECTIV Is the M function effective at the
beginning or end of block (only M0 to
M88 and M300 to M999)?
WAIT Only for M functions that do not call
NC macros:
Should the NC wait for
acknowledgment from the PLC (only
for M0 to M88 and M300 to M999)?
If there is no entry in this column,
MP7440 bit 2 is valid.
MANLOCK Is the M function locked in the
manual operating modes?
NONESTED May the macro not be called by
another macro?
RK Should the macro stored for the M
function also be used for active radius
compensation (RR/RL)?
Until now, the error message Cancel
radius comp. before PLC pos. was
displayed. A macro that can also be
run during active radius
compensation should only contain NC
functions that do not influence radius
compensation in the calling program.
A maximum of 30 NC programs can be nested (subprograms, cycles,
macros).