1342 HEIDENHAIN Technical Manual iTNC 530 HSCI
For the connection of the IPC 6341, HEIDENHAIN recommends using the
RDP connection. With RDP, the screen of the external computer is not
mirrored, as with VNC, but an individual desktop is opened for it. The desktop
that is active on the external computer when the connection is established is
then locked and the user is logged off. This prevents operation from two sides.
The user "TNC" should be defined right from the start in the settings of the
connection to the IPC 6341.
Also, with an RDP connection it is not possible to completely shut down the
external computer via the Windows menu. It is only possible to cancel the
connection or log off the user.
The RDP connection also adjusts the screen resolution automatically.
Please note that an RDP connection is closed again automatically after 30
seconds if no user name and password were configured for it or if the user has
not logged on within this time. The Automatic starting upon login function
therefore only makes sense if a user with user name and password was
configured.
Details
Computer: Host name or IP address of the external
computer. In the recommended
configuration of the IPC 6341, it is the IP
address 198.168.254.3.
Password: The default password for connection to the
VNC server is "123". Please change this
password on the IPC and TNC during
commissioning.
Windows domain Domain of the target computer, if required.
Full-screen
mode
Show display of the external computer in
full-screen mode. Only useful, if the
resolution of the external computer
matches the resolution of the control
screen (BF).
User-defined
window size
Definition of the window size for the display
of the external computer or connection. As
a rule, the window size should correspond
to the resolution of the external computer
or connection, as long as it is lower than the
resolution of the control screen.
Expanded options Advanced settings that are usually not
necessary. Only in consultation with
HEIDENHAIN.
Menu item Function