1386 HEIDENHAIN Technical Manual iTNC 530 HSCI
The following definitions are possible:
Entries for the menu definition and type of soft key in the HR 420/HR 5xx
menu:
Entry Parameter Description
; Comment
SKMENU <menu name>
ENDSKMENU
Beginning or end of the definition of a soft-key
menu. The name of the menu must be given for
SKMENU (e.g. "HRRootMenu"—see the example).
The soft keys are aligned on the HR in the
sequence in which they appear in the file. Also
note the additional parameters for this keyword.
HRROOT Freely-definable root menu when called from the
basic handwheel menu via the FCT (Function) soft
key
HRMENU Freely-definable submenu, called via the keyword
NODE ...
TITLE:<name> Menu title: Freely definable text in the third line of
the HR 420/HR 5xx
The parameter TITLE: can also be surrounded by
quotation marks. This permits blank spaces in the
menu title.
NODE <submenu name> Soft key jumps to a submenu. Is confirmed via W306 to the PLC. The
soft-key name and the name of the submenu must be indicated.
BACK Soft key jumps to a submenu. Is confirmed via W306 to the PLC. The
soft-key name and the name of the submenu must be indicated.
BLANK Empty soft key, is shown as "..". You can also specify a soft-key name.
ACTION <soft-key name> Function soft key. Is confirmed via W306 to the
PLC. The soft-key name must be indicated.
STATUS:<marker or
word>
An operand is assigned to the soft key (in addition
to W306). If a marker is indicated and the soft key
is pressed, the marker is set. If a word is indicated,
the soft key number is entered (index number in
the *.sys file, e.g. Softkey.sys).
PULSE <soft-key name> The soft key is reported to the PLC via W306 for the duration of the PLC
cycle. A soft-key name must be indicated.
The soft-key types RADIO, CHECK and STATE may not be used. Other parameters, such as ENABLE,
HIDE, REPEAT, etc. are not yet available.