148 HEIDENHAIN Technical Manual iTNC 530 HSCI
The OEM key was added to the display and management of the SIK options,
feature content level and general key on the control. Press the MOD key and
enter the code number SIK to display the input form for SIK functions:
OEM Key
The OEM Key on the control can only be used for enabling software options
with a temporary code number if the same OEM Key was specified for the
generation of the temporary code number.
If the OEM Key on the control is not identical to the one used for generating
the code number, the software option will not be enabled. Once the OEM
Key has been set, it cannot be reset.
Display Meaning
OEM Key for
temp. options
NONE OEM Key was not set
SET OEM Key was set
Set OEM Key Press the Set OEM Key button or the SET OEM KEY
TEMP. OPT. soft key to open a window in which you
can enter the OEM Key.
Keep in mind that this process cannot be undone.
The OEM Key must consist only of numbers.
Confirm your entry by pressing the Apply button, or
by pressing the SET OEM KEY TEMP. OPT. soft key
again.
If the OEM Key was set successfully, the message
OEM Key has been set appears, and the status in OEM
Key for temp. options changes to SET.