July 2013 8.15 Tool changer 1567
MP7260 Number of tools in the tool table
Input: 0 to 30 000
MP7261.0-15 Number of pockets in the tool magazine 1 to 16
Input: 0 to 9999
MP7263 Pocket table
Format: %xxxxxxx
Input: Bit 0
0: POCKET TABLE soft key is shown
1: POCKET TABLE soft key is hidden
Bit 1 – Output of the pocket table for file functions
0: Output only the displayed columns
1: Output all columns
Bit 2 – Show the "Edit ON/OFF" soft key in the pocket table
0: Display soft key
1: Do not display soft key
Bit 3 – Display the RESET POCKET TABLE and RESET
COLUMN T soft keys in the pocket table
0: Display soft key
1: Do not display soft key
Bit 4 - Deletion possible for a tool that is in the pocket table.
Deletion must be confirmed.
0: Deletion impossible
1: Deletion possible (with confirmation)
Bit 5 – Deletion of a tool possible even without confirmation (if
bit 4 = 1)
0: Deletion not possible without confirmation
1: Deletion possible without confirmation
Bit 6 – Deletion of index entries of a tool behaves like deletion
of a tool. The settings of bits 4 and 5 also apply to the index
entries if bit 6 is set.
0: Deletion always impossible
1: Deletion possible depending on settings in bits 4 and 5
MP7266 Elements of the tool table
Input: 0 = no display
1 to 99 = position in the tool table
MP7682 MP with multiple function
Input: Bit 12 – Error message "Tool radius too large" if R2 > R
0 = Error message displayed
1 = Error message is not displayed
MP4020 PLC functions
Input: Bit 15 – Saving the changes to tables to memory medium (HDR,
SSDR)
0: Cyclic saving of tables (behavior same as up to and including
60642x-01 SP 04)
1: Save tables each time they are closed