202 HEIDENHAIN Technical Manual iTNC 530 HSCI
With the following HSCI control components, you must also make a
distinction between those that are required in a system with functional safety
and those that can be used in a system without functional safety. Devices with
FS are listed below in the middle column:
Device designation Device ID for systems
with integrated FS
Device ID for systems
without integrated FS
Machine operating panels and keyboard units
In systems with FS you must use a machine operating panel for functional-
safety applications. In these operating panels, all keys have twin channels. A
movement can therefore be executed without additional permissive button/
key.
MB 620 (FS) 660090-xx 617973-xx
TE 635Q (FS) 662255-xx 617975-xx
TE 645Q(FS) 685394-xx 682104-xx
MB 720(FS) 805474-xx 784803-xx
TE 735 (FS) 805493-xx 771898-xx
TE 745 (FS) 805482-xx 679817-xx
PLB basic modules
In FS systems, mixed use of PLB basic modules with and without FS is
possible. However, at least one PLB 62xx FS must be used in systems with
FS.
PLB 6104 (FS) 590479-xx 591828-xx
PLB 6106 (FS) 804755-xx 630058-xx
PLB 6108 (FS) 804756-xx 630059-xx
PLB 6204 (FS) 586789-xx 591832-xx
PLB 6206 (FS) 622721-xx 630054-xx
PLB 6208 (FS) 620927-xx 630055-xx
PLB 6001 (FS) Not yet available 668792-xx
PLD-H I/O modules
In systems with FS, the mixed use of PLD-H modules with and without FS is
possible in PLB basic modules with FS. However, do not insert PLD-H
modules with FS in PLB basic modules without FS. Furthermore, the
modules with FS must always be inserted into the PLB with FS starting from
the left.
PLD-H 16-08-00,
PLD-H 08-04-00 FS
598905-xx 594 243
PLD-H 08-16-00,
PLD-H 04-08-00 FS
727219-xx-xx 650891-xx