July 2013 3.30 HSCI adapter for PLB 6001 (FS) OEM-specific machine operating panel 351
X161 to X168:
PLC inputs
PLB 6001 without FS:
0 V PLC must be connected to terminal 1.
X161: PLC inputs
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 0 V PLCI0I1I2I3I4I5I6I7
X162: PLC inputs
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 0 V PLC I8 I9 I10 I11 I12 I13 I14 I15
X163: PLC inputs
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 0 V PLC I16 I17 I18 I19 I20 I21 I22 I23
X164: PLC inputs
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 0 V PLC I24 I25 I26 I27 I28 I29 I30 I31
X165: PLC inputs
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 0 V PLC I32 I33 I34 I35 I36 I37 I38 I39
X166: PLC inputs
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 0 V PLC I40 I41 I42 I43 I44 I45 I46 I47
X167: PLC inputs
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 0 V PLC I48 I49 I50 I51 I52 I53 I54 I55
X168: PLC inputs
Assignment Terminal
1 2 3 4 5 6 7 8 9
PLB 6001 0 V PLC I56 I57 I58 I59 I60 I61 I62 I63