July 2013 4.4 List of machine parameters 567
MP7620 Feed-rate override and spindle speed override
Format: %xxxxxxx
Input: Bit 0 – Feed-rate override if rapid traverse key is
pressed in Program Run mode.
0: Override not effective
1: Override effective
Bit 1 – No function
Bit 2 – Feed-rate override if rapid traverse key and machine
direction button are pressed in Manual Operation
mode
0: Override not effective
1: Override effective
Bit 3 – for TEs without rapid traverse override:
0:
Linear characteristic curve for spindle override and feed rate
override; unit depends on bit 4 0..150 or 0..15000
1: Non-linear characteristic curve for spindle override and
feed rate override, unit 0..15000
Bit 4 – for TEs without rapid traverse override:
0: Spindle override and feed rate override with unit 0 to 150
1: Spindle override and feed rate override with
unit 0..15000
Bit 3 – for TEs with rapid traverse override:
0: Linear characteristic curve for spindle-speed and feed-
rate override, unit 0..15000
1: Non-linear characteristic curve for spindle override and
feed rate override, unit 0..15000
Bit 4 – for TEs with rapid traverse override:
No effect
Bit 5 – Rapid traverse override instead of spindle override
0: Potentiometer is used for spindle override
1: Potentiometer is used for rapid-traverse override
Bit 6 – Feed-rate smoothing
0: Not active
1: Active
Bit 7 – Only with functional safety:
Adjust potentiometer to F-LIMIT
0: Do not adjust potentiometer to F-LIMIT
1: Adjust potentiometer to F-LIMIT, 100 % corresponds to
active SLS limit
Bit 8 – Informational text if feed-rate or rapid-traverse
override is set to 0 %
0: Informational text inactive
1: Informational text active
Bit 9 – HSCI keyboard with three potentiometers
0: Keyboard unit with two potentiometers
1: Keyboard unit for HSCI with three potentiometers
PLC
RUN
358,
963,
1156
MP7621 Reserved
MP7630 Recovery time after emergency stop test can be configured
Input: 1 to 999 [ms]
0: 200 ms
PLC
RUN
936