982 HEIDENHAIN Technical Manual iTNC 530 HSCI
The diagram shows in principle how you can determine the switchover speeds
for the wye/delta switchover:
1: Lower switching speed = n(intersection) – 2% to 4% of nmax
2: Speed at which the two characteristic curves intersect:
n(intersection) at n(S1_wye) = n(S1_delta)
3: Upper switching speed = n(intersection) + 2% to 4% of nmax
MP2223.x Bit 3—Wait for readiness of current controller
Format: %xxxxxxxxxxxxxxxx
Input: 0: Wait for readiness of current controller
1: Do not wait for readiness of current controller
Danger
The contactor for the wye/delta switchover must not be switched under
load!
Attention
On machines with transmission or wye/delta switchover, the RPM
FACTOR (Q403) function of Cycle 209 (Tapping with chip breaking) must
not be used with a value other than the default value. Switching the gear
range or wye/delta switchover during retraction with the RPM FACTOR
function may cause damage to the machine.
Please inform the customers who are using these types of machines that
the RPM FACTOR (Q403) function of Cycle 209 (Tapping with chip
breaking) must not be used with a value other than the default value.
Synchronous motors may only be switched at standstill. Switching a
rotating synchronous motor is not possible.