GUI reference
R&S
®
ZNA
345User Manual 1178.6462.02 ─ 29
Setup
Opens the S-Params setup dialog.
S-Parameter (selector)
Selects an S-parameters as a measured quantity for the active trace.
Single-ended (unbalanced) S-parameters are referred to as S<out>< in>, where <out>
and <in> denote the output and input logical port numbers, respectively.
If entered manually, <out> and <in> must be expressed using the same number of dig-
its. I.e. for <out>=10 and <in>=9 you can specify S<out>< in> as S1009 or S010009,
but not as S109.
In presence of balanced ports, standard S-parameters are defined in the form
S<m_out><m_in><out><in>, where output mode <m_out> and input mode <m_in> can
be one of:
d (differential, balanced)
c (common, balanced)
s (single-ended, unbalanced)
It is also possible to display "raw" single-ended S-parameters within the same channel:
after setting the S-Parameter type to "S" any pair of (used) physical ports can be
selected.