GUI reference
R&S
®
ZNA
494User Manual 1178.6462.02 ─ 29
The appearance of the limit fail symbols is defined in the "Define User Color Scheme"
dialog (see Chapter 5.18.3.2, "Define User Color Scheme dialog", on page 847). You
can choose between various options:
●
Change the trace color between failed measurement points.
●
Show or hide the colored squares.
Note:
●
Circle limit check and display of limit circles are independent of each other:
– The limit circles can be displayed, no matter if the circle limit check is enabled.
– If "Limit Check" is enabled, the ripple limits are checked, no matter if they are
displayed.
●
If result evaluation is limited to a user-defined display circle, the Chapter 5.6.3,
"Circle Test tab", on page 492 is only performed inside this display circle.
●
The circle limits can only be checked if the trace format is complex. While a carte-
sian format is active, the limit circles are hidden and the circle limit check is sus-
pended.
●
If the limit check for (cartesian) limit lines is enabled, it is also evaluated in complex
diagrams.
Lines softtool