EasyManua.ls Logo

Rohde & Schwarz R&S ZNA Series - Page 996

Rohde & Schwarz R&S ZNA Series
1849 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
996User Manual 1178.6462.02 ─ 29
Dirac jitter insertion can be enabled using CALCulate<Chn>:EYE:JITTer:TYPE:
PERiodic.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<DiracDelta> *RST: 1 ns
Default unit: s
Options: R&S ZNA-K20
Manual operation: See "Dirac" on page 817
CALCulate<Chn>:EYE:JITTer:DIRac:PROBability <DiracProbability>
Defines the probability of the Dirac jitter in the generator simulation of the related eye
diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Dirac jitter insertion can be enabled using CALCulate<Chn>:EYE:JITTer:TYPE:
PERiodic.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<DiracProbability> Probability of the jitter occurring at each symbol period
*RST: 0.5
Options: R&S ZNA-K20
Manual operation: See "Dirac" on page 817
CALCulate<Chn>:EYE:JITTer:PERiodic:FREQuency <PeriodicFrequency>
Defines the frequency of the periodic jitter in the generator simulation of the related eye
diagram.
This command will raise an execution error if the active trace in the selected channel is
not an eye diagram.
Periodic jitter insertion can be enabled using CALCulate<Chn>:EYE:JITTer:TYPE:
PERiodic.
Suffix:
<Chn>
.
Channel number used to identify the active trace
Parameters:
<PeriodicFrequency> *RST: 10 MHz
Default unit: Hz
Options: R&S ZNA-K20
SCPI command reference

Table of Contents

Related product manuals