1702 HEIDENHAIN Technical Manual iTNC 530 HSCI
FIXTURE.
FUNCTION =
Activating fixture monitoring in combination with collision monitoring DCM.
Input example: FIXTURE.FUNCTION = YES
IOCCFG = Complete configuration of the HSCI system as an IOC file. This is done using
the IOconfig tool.
Input example: IOCCFG = PLC:\IOC\HSCI_SYS.IOC
KINEMATIC = Path for the assignment table of the tilting-axis geometry description.
Input example: KINEMATIC = PLC:\KINELIST.TAB
LOCKEDOPTIONS = You can use the LOCKEDOPTIONS = keyword to select software options that will
not be enabled with the General Key. <option> is the number of the software
option to be disabled. This way you can disable those software options for
which your machine is not prepared.
Input example: LOCKEDOPTIONS = 44,45
LOGO = Path for customer-specific company logo during control power-up.
Input example: LOGO = PLC:\LOGO\OEM-LOGO.BMP
LOGOSP = Path for a customer-specific company logo shown when the control is started,
instead of the note regarding an installed service pack.
Input example: LOGOSP = PLC:\LOGO\SP-LOGO.BMP
LSV2TIME0 = Timeout for block reception (STX to ETX).
LSV2TIME1 = Timeout for acknowledging ENQ or check sum.
LSV2TIME2 = Timeout during transmission of DLE 0, DLE 1 or NAK until reception of a valid
character.
MODEHELP = Path for help texts and machine commands.
Input example: MODEHELP = PLC:\LANGUAGE\GERMAN\OPTIMIER.HLP
MPFILE = (Mandatory entry): Path for the active MP file. If you have loaded an MP file
editor and you exit the editor, the iTNC automatically enters this MP file in the
OEM.SYS file!
Input example: MPFILE = PLC:\MP\NC530V02.MP