July 2013 9.4 System Files 1703
MPFRAGMENT
<Value> =
Up to 10 (<value> from 0 to 9) machine parameter subfiles can be defined.
They can be activated with FN17: SYSWRITE ID1020 NR1 = <value>. Changes
to the spindle machine parameters (MP3xxx or MP13xxx) are only active after
an S output. All other machine parameters are active immediately. The
changes also remain in effect if a new NC program is selected, but not if the
control is restarted.
Input example: MPFRAGMENT0 = PLC:\MP\FINISH.MP
MPFRAGMENTFILE
=<path/file name>
By entering MPFRAGMENTFILE = <path\file name>, you specify a file containing
the paths to machine-parameter subfiles and the file names, which can be
activated via FN17.
The value entered in the FN17 SYSWRITE ID 1020 NR1 = <line number> function
then corresponds to the MP subfile reference in this file.
This makes it possible to enter any number of MP subfiles (until now only 10
files MPFRAGMENT0-9 = <path>).
Changes to spindle machine parameters (MP3xxx or MP13xxx) are only active
after an S output. All other machine parameters are active immediately.
The changes also remain in effect if a new NC program is selected, but not if
the control is restarted.
Input example: MPFRAGMENTFILE = PLC:\MP\MPFILELIST.MP
MPLOCKFILE = Path of a machine parameter subfile. If there are differences between this file
and the current machine parameter file, an error message appears and the
value from this subfile is offered for acceptance.
Input example: MPLOCKFILE = PLC:\MP\340420.MPL
MPPASSWORD = Code number for calling the machine parameter file (instead of 95148).
Input example: MPPASSWORD = MP
Please note that MPFRAGMENTx and MPFRAGMENTFILE... of course cannot be
used as keywords at the same time.
Please note that MPFRAGMENTx and MPFRAGMENTFILE... of course cannot be
used as keywords at the same time.
Do not enter a code number that has already been defined by
HEIDENHAIN!