July 2013 9.5 Data Transfer NC > PLC, PLC > NC 1721
Write values into the active preset table
502 Line Column Write value with conversion from the
currently active coordinate system
into the preset table
503 Line Column Write value into the preset table
without conversion
504 Line Column Write basic rotation into the preset
table
530 1 – Activate preset
Pallet preset table
540 1 – Active line in the pallet preset table
Save machine statuses
590 1 1 to 9 "Variables" 1 to 9 can only be read
with FN18: SYSREAD ID590 NR1.
Deletion depends on MP7300.
21 to 9
(X, Y, Z, A, B, C,
U, V, W)
The "variables" for ID621.
Independent of MP7300.
31 to 9
(X, Y, Z, A, B, C,
U, V, W)
The "variables" for ID621.
Independent of a power failure.
621 0 1 to 9
(X, Y, Z, A, B, C,
U, V, W)
Stop measurement of the dynamic
load and save the result.
Velocity semifeedforward control
600 1 Axis Factor for velocity semifeedforward
2 0 or NO ENT Use factor from MP1396.x
Adaptive Feed Control (AFC)
622 0 0.0 0: AFC not active
1: AFC active
Group
name
Group
number
ID....
System data
number
NR....
System data
index
IDX....
System datum