July 2013 10.3 Connecting the iTNC to the Network 1883
Error code:
Module 9287 General status requests regarding VNC clients
PLC Module 9287 is used to program the following status requests regarding
control and assignment of multiple operator terminals (IPC, thin client):
Number of VNC clients
Status of focus assignment
Name of the active VNC client (master)
List of VNC clients
Individual name of a VNC client from the client list
Constraints:
Call only from a submit/spawn job
If no name is configured for a client, its MAC address is returned in the PLC
strings.
Mode 3/4: The sequence and numbering of the client list can vary from one
boot instance to the next, since this information depends on the point in
time at which the clients register themselves in the system.
Marker Value Meaning
M4203 0 No error
1 Faulty execution of module
W1022 1 Mode parameter is invalid
2 Timeout parameter or additional parameter parameter
is invalid
3 PLC string address parameter invalid
20 Call was not in a submit/spawn job
45 PLC module cancelled (operating-system error)
51 NC software does not support module
61 Function could not be executed
100 Invalid parameter
110 Focus assignment unclear, currently no master
111 Client could not be set as master
120, 121,
122
Disabling of focus assignment not supported
130 Unknown status of focus assignment
131, 132,
133, 134
Interference in communication for focus assignment
200, 201 Internal error