July 2013 10.3 Connecting the iTNC to the Network 1885
Error code:
Module 9288 Status requests regarding a VNC client
PLC Module 9288 (call only from within a submit/spawn job) is used to
program the following status requests regarding control and assignment of
multiple operator terminals (IPC):
Properties of a client (master / can be master / can be displayed)
Constraints:
Call only from a submit/spawn job.
The names of the clients (host name or MAC address) can be ascertained
with Module 9287.
Marker Value Meaning
M4203 0 No error
1 Faulty execution of module
W1022 1 Mode parameter is invalid
2 Timeout parameter or additional parameter parameter
is invalid
3 PLC string address parameter invalid
11 List of clients is empty
12 Error while evaluating the client list
20 Call was not in a submit/spawn job
45 PLC module cancelled (operating-system error)
51 NC software does not support module
61 Function could not be executed
100 Invalid parameter
110 Focus assignment unclear, currently no master
111 Client could not be set as master
120, 121,
122
Disabling of focus assignment not supported
130 Unknown status of focus assignment
131, 132,
133, 134
Interference in communication for focus assignment
200, 201 Internal error