July 2013 3.30 HSCI adapter for PLB 6001 (FS) OEM-specific machine operating panel 349
Please note that the PLB 6001 (FS) is supplied with +24 V NC.
For the entire HSCI system, the +24 V NC supply voltage is required to be
safely separated voltage. The +24 V NC supply voltage must not, under any
circumstances, be connected with the +24 V PLC supply voltage, because
this removes the double basic insulation.
The interface is electrically separated (protective extra-low voltage (PELV)
as per EN 61800-5-1).