390 HEIDENHAIN Technical Manual iTNC 530 HSCI
This results in a unique state that must be achieved after the machine has
been switched on and no permissive button is pressed. At the handwheel
adapter (ID 296466-xx) this state is X1/1 = 0, X1/2 = 0 for standard
handwheels and X1/1 = 0, X1/2 = 1 for FS handwheels. The same state must
also be achieved if the corresponding dummy plug is used. The PLC program
should check this unique state when the machine is switched on, to make
sure that the correct handwheel or dummy plug for the respective machine
configuration is connected. If the expected state is not achieved, an error
message is to be triggered and the machine operator is to be prompted to
attach the correct handwheel or dummy plug. Using an incorrect handwheel
or dummy plug leads to a PLC input (one channel) always carrying the
information that a permissive button is pressed.
Pin layout of dummy plug for FS:
General notes on
handling and
operation
Please note the following information when using handwheels and dummy
plugs, and also give this information to your customers:
Dummy plug for FS ID 271958-05
Pin Assignment
1 Bridge on pin 2 (permissive button)
2 Bridge on pin 1 (permissive button)
3 Not assigned
4 Bridge on pin 4 (emergency stop)
5 Bridge on pin 5 (emergency stop)
6 Bridge on pin 7 (emergency stop)
7 Bridge on pin 6 (emergency stop)
8 Not assigned
A Not assigned
B Not assigned
C Not assigned
D Not assigned
Only qualified personnel may connect and exchange handwheels and
dummy plugs.
It is essential that operative actions (such as pressing the emergency
stop) on handwheels that are not connected are not possible.
Handwheels and dummy plugs that are not connected to the machine,
and are therefore without function, must be removed from the machine.
Handwheels and dummy plugs that are not being used must clearly be
stored away from the machine, such as in a locked cabinet.
Only FS handwheels and dummy plugs for FS handwheels (ID 271958-05)
may be used on systems that are prepared for FS handwheels.
Only standard handwheels and dummy plugs for standard handwheels
(ID 271958-03) may be used on systems that are prepared for standard
handwheels (without FS).