520 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP2450.x Dead-time compensation
Input: 0: Dead-time compensation not active
1: Dead-time compensation active
PLC 869
MP2500.x Proportional factor of the speed controller
Input: 0 to 1 000 000.000 [As]
PLC
RUN
848
MP2510.x Integral factor of the speed controller
Input: 0 to 100 000 000 [A]
PLC
RUN
848
MP2512.x Limit of integral factor of the speed controller
Input: 0.000 to 30.000 [s] (realistic values: 0.1 to 2.0)
PLC
RUN
661,
854
MP2520.x Differential factor of the speed controller
Input: 0 to 1.0000 [As]
PLC
RUN
850
MP2530.x PT
2
element of the speed controller (second-order time
delay element)
Input: 0 to 1.0000 [s]
PLC
RUN
851
MP2540.x Reserved PLC
RUN
851
MP2542.x Damping/phase increase for filter 1
Input: 0 to 40.0 [dB]
PLC
RUN
1090
MP2543.x Damping/phase increase for filter 2
Input: 0 to 40.0 [dB]
PLC
RUN
1090
MP2544.x Damping/phase increase for filter 3
Input: 0 to 40.0 [dB]
PLC
RUN
1090
MP2545.x Damping/phase increase for filter 4
Input: 0 to 40.0 [dB]
PLC
RUN
1090
MP2546.x Damping/phase increase for filter 5
Input: 0 to 40.0 [dB]
PLC
RUN
1090
MP2547.x Damping/phase increase for filter 6
Input: 0 to 40.0 [dB]
606420-03
PLC
RUN
1090
MP2550.x Reserved PLC
RUN
851
MP2552.x Center/cutoff frequency for filter 1
Input: 0 to 30000.0 [Hz]
PLC
RUN
1090
MP2553.x Center/cutoff frequency for filter 2
Input: 0 to 30000.0 [Hz]
PLC
RUN
1090
MP2554.x Center/cutoff frequency for filter 3
Input: 0 to 30000.0 [Hz]
PLC
RUN
1090
MP2555.x Center/cutoff frequency for filter 4
Input: 0 to 30000.0 [Hz]
PLC
RUN
1090