522 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP2565.x Filter type for filter 4
Input: 0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
3: Phase increase (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
13: Phase increase (position controller)
PLC
RUN
1091
MP2566.x Filter type for filter 5
Input: 0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
3: Phase increase (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
13: Phase increase (position controller)
PLC
RUN
1091
MP2567.x Filter type for filter 8
Input: 0: No filter
1: PT2 low-pass filter (speed controller)
2: Band-rejection filter (speed controller)
3: Phase increase (speed controller)
11: PT2 low-pass filter (position controller)
12: Band-rejection filter (position controller)
13: Phase increase (position controller)
606420-03
PLC
RUN
1091
MP2572.x Bandwidth for filter 1
Input: 0 to 30000.0 [Hz]
PLC
RUN
1092
MP2573.x Bandwidth for filter 2
Input: 0 to 30000.0 [Hz]
PLC
RUN
1092
MP2574.x Bandwidth for filter 3
Input: 0 to 30000.0 [Hz]
PLC
RUN
1092
MP2575.x Bandwidth for filter 4
Input: 0 to 30000.0 [Hz]
PLC
RUN
1092
MP2576.x Bandwidth for filter 5
Input: 0 to 30000.0 [Hz]
606420-03
PLC
RUN
1092
MP2577.x Bandwidth for filter 5
Input: 0 to 30000.0 [Hz]
PLC
RUN
1092
MP2590.x Braking ramp in an emergency stop
Input: 0.001 to 999.999 [min
–1
/ms]
0: Function inactive
PLC
RUN
871
MP2600.x Acceleration feedforward control
Input: 0 to 100.0000 [A/(rev/s2)]
PLC 854
MP Function and input Software
version and
behavior