704 HEIDENHAIN Technical Manual iTNC 530 HSCI
Step 3
Probe surface X1
Entry for the kinematics
•Via table: <Line no. [1] Column COORD> = –0.5 * determined value
Step 4a
Position C to 0
Probe surface X2
L = determined value