July 2013 6.5 Tilting and swivel axes 705
Step 4b
Position B to –90
Probe surface X1
ΔX1 = determined value
Position B to +90
Probe surface X2
ΔX2 = determined value
Entry for the kinematics
Via table: <Line no. [3] Column COORD> = {[0.5 * (ΔX2 – ΔX1 – L – 2*(probe length) + 2*(ball
radius))] – MP7530.0} / cos 4
Step 4c
Position B to –90
Probe surface Z
Set Z = 0
Position B to +90
Probe surface Z
Entry for the kinematics
•Via table: <Line no. [6] Column COORD> = (–0.5 * determined value) – <Line no. [1] Column
COORD>
Step 5
Probe surfaces X1, X2, Y2 and Z in a tilted working plane with the tilting angles B = –90, B = +90
and C = 180
If there are differences between the individual tilting angles, the offsets from line numbers [0] and
[3] in the kinematics table should be determined with a different process (steps 6 to 8), and the
averages from both processes should be entered in line numbers [0] and [3] in the kinematics table.