July 2013 6.13 Integrated oscilloscope 995
Colors In MP7365.x, define the colors for the oscilloscope.
Setup
Activate the oscilloscope with the DIAGNOSIS, DRIVE DIAGNOSTICS and
OSCI soft keys.
The setup menu appears:
Choose the parameters to be entered with the cursor keys.
The oscilloscope can be operated with reduced functions starting from the
Power interrupted message. If you enter the code number DSP123 before
calling the oscilloscope, then starting from the Power interrupted message
the data are recorded and can be displayed via the oscilloscope.
A step response is not possible. In order to make a step response possible,
the keyword 688379 must have already been entered.
Please note that the control has not finished booting at this time, and that
the displayed values can therefore deviate from the correct or expected
values.