EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - Page 996

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
996 HEIDENHAIN Technical Manual iTNC 530 HSCI
Operating mode:
Select the desired setting or choose the circular interpolation test
YT: Chronological depiction of the channels
XY: X/Y graph of two channels
CIRC: Circular interpolation test
Sample time:
Set the time interval for recording the signals.
Possible entries: 0.6 ms, 1.8 ms and 3.6 ms
4096 samples are stored. The signals are therefore stored for the following
duration:
0.6 ms 4096 = 2.4576 s
1.8 ms 4096 = 7.3728 s
3.6 ms 4096 = 14.7456 s
Output:
Select whether the nominal speed value is to be issued as a step or ramp.
If you select ramp output, then the programmed feed rate, k
V
factors, and
acceleration values that you have specified with machine parameters go
into effect.
If you select step output, a step will be output as nominal velocity value
when you press the axis-direction buttons in the Manual operating mode.
During output, the position control loop is open. A step can be output only
if code number 688379 or 807667 has been entered.
Feed rate:
Enter the height of the step for the nominal velocity value (in mm/min). This
entry has no effect for ramp output.
Channel 1 to channel 6:
Assign the channels of the recorded signals to the respective axes.
Trigger:
Define the type of recording.
You have the following possibilities:
Free run: The recording is started and ended by soft key. When you press
the STOP soft key, the last 4096 events are saved.
Single shot: When you press the START soft key, the next 4096 events
are saved.
Channel 1 to channel 6: Recording begins as soon as the trigger threshold
for the set channel is crossed.