EasyManua.ls Logo

Rohde & Schwarz R&S ZNA Series - Page 1039

Rohde & Schwarz R&S ZNA Series
1849 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Command reference
R&S
®
ZNA
1039User Manual 1178.6462.02 ─ 29
CALCulate:FMODel:ISD:PRESet...................................................................................1045
CALCulate:FMODel:ISD:RUN:RUN............................................................................... 1045
CALCulate:FMODel:ISD<Pt>:RUN[:STATe].....................................................................1046
CALCulate:FMODel:ISD:SCALe:ATTenuation................................................................. 1046
CALCulate:FMODel:ISD:SCALe:FREQuency..................................................................1046
CALCulate:FMODel:ISD:SCALe:FTIMe..........................................................................1046
CALCulate:FMODel:ISD:SMALlfixture............................................................................ 1046
CALCulate:FMODel:ISD:TRACe:COUPling.....................................................................1047
CALCulate:FMODel:ISD:ATTenuation:BEHavior <AttenuationBehavior>
Sets/gets the linear_2x batch mode parameter of the ISD tool
Parameters:
<AttenuationBehavior>RESonant | LINear | NONLinear
LINear
Used for linear insertion loss of test coupon (parameter value 1)
NONLinear
Used for non-linear insertion loss of test coupon (parameter
value 2)
RESonant
The 2x thru test coupon will be split and used directly for deem-
bedding (parameter value 3).
This option may be more accurate when the fixture and 2x Thru
have the same impedance at every location
Manual operation:
See "Test Coupons > Insertion Loss" on page 737
CALCulate:FMODel:ISD:COUPon:MEASure
For a fixture modeling with the ISD tool and coupon types SYMMetric2x | OPEN1x |
SHORt1x (see CALCulate:FMODel:ISD:COUPon:TYPE), this command starts the
measurement of the coupon at the active ports (see CALCulate:FMODel:
ISD<Ph_pt>:COUPon[:STATe]).
Example:
See Chapter 8.2.9, "Fixture modeling", on page 1762
Usage: Event
Manual operation: See "Measure / Measure Open / Measure Short" on page 731
CALCulate:FMODel:ISD:COUPon:MEASure:FILename <String>
For a fixture modeling with the ISD tool and coupon types SYMMetric2x | OPEN1x |
SHORt1x (see CALCulate:FMODel:ISD:COUPon:TYPE), this command loads the
coupon properties from a Touchstone file.
Parameters:
<String> Path to the Touchstone file, either absolute or relative to the
selected working directory (CALCulate:FMODel:DIRectory).
SCPI command reference

Table of Contents

Related product manuals