Command reference
R&S
®
ZNA
1286User Manual 1178.6462.02 ─ 29
BOTH
Both positions
(parameter omitted)
If the parameter is omitted, the command refers to the two-port
selected using SOURce<Ch>:POWer<PhyPt>:CORRection:
TCOefficient:CALibration.
Setting parameters:
<TraceFile> String parameter specifying the name and directory of the loa-
ded trace file. The R&S ZNA supports power meter correction
list files (*.pmcl, generated using MMEMory:STORe:
CORRection:TCOefficient<Ch>), *csv, and Touchstone
(*.s1p, *.s2p, ...) files.
If no path is specified the analyzer searches the current direc-
tory, to be queried with MMEMory:CDIRectory
The file extensions *.s<n>p, *csv, and *.pmcl for Touch-
stone, ASCII, and power meter correction list files are manda-
tory.
*RST: n/a
<Trace> Optional string parameter: For multiport Touchstone files
(*.snp, n > 1), the parameter refers to a particular S-parame-
ter trace ('S11', 'S12', ...). For ASCII (*.csv) files, the
parameter references a trace name in the file (case sensitive). If
the parameter is omitted, the first trace in the specified file is
imported.
This parameter is not used for power meter correction list files
(*.pmcl).
*RST: n/a
Example: See SOURce:POWer:CORRection:TCOefficient[:STATe]
on page 1563
Usage: Setting only
Manual operation: See "Import File..." on page 634
MMEMory:LOAD:EYE:BPATtern <TraceName>, <TraceFile>
Loads a user-defined bit pattern for the related eye diagram from a 7-bit ASCII file.
The pattern is repeated until the configured length is reached (see CALCulate<Chn>:
EYE:INPut:LENGth:BITS on page 993).
Loading a pattern from file implicitly sets the type of bit stream to USER (see
CALCulate<Chn>:EYE:INPut:BPATtern:TYPE).
Setting parameters:
<TraceName> Name of the related eye diagram