Command reference
R&S
®
ZNA
1454User Manual 1178.6462.02 ─ 29
Setting parameters:
<ReceivePort> Receiving test port number
<DrivePort> Driving test port number
<further port pairs> Additional receive/drive port pairs (comma-separated)
Example:
SENSe1:NFIGure:DEFine 2,1
Initiates a noise figure measurement in channel 1, with drive port
1 and receive port 2.
Options: R&S ZNA-K30
Manual operation: See "Driving Port (RF) / Receiving Port (IF)" on page 370
[SENSe<Ch>:]NFIGure:GTIMe <DetectorTime>
Defines the detector time of the AVG detector which is used for the gain measurement
during a NF measurement in channel <Ch>
Suffix:
<Ch>
.
Channel number
Parameters:
<DetectorTime> Detector time for the AVG detector
Default unit: s
Example:
SENSe1:NFIGure:GTIMe 10ms
Options: R&S ZNA-K30
Manual operation: See "Gain Det Meas Time" on page 372
[SENSe<Ch>:]NFIGure:HARMonic[:MAXFrequency] <FrequencyLimit>
[SENSe<Ch>:]NFIGure:HARMonic[:MINFrequency] <FrequencyLimit>
Sets the lower|upper frequency limit to which the sideband correction is used in a noise
figure measurement in channel <Ch>.
Suffix:
<Ch>
.
Channel number
Parameters:
<FrequencyLimit> Frequency limit at which the noise figure sideband correction is
used.
Range: 10 MHz | 9 GHz
Default unit: Hz
Options: R&S ZNA-K30
Manual operation: See "Sideband Correction" on page 375