1734 HEIDENHAIN Technical Manual iTNC 530 HSCI
Read machine statuses
590 1 1 to 9 "Variables" 1 to 9 can only be written
with FN17: SYSWRITE ID590 NR1.
Deletion depends on MP7300.
590 2 1 to 9
(X, Y, Z, A, B, C,
U, V, W)
The "variables" for ID621.
Independent of MP7300.
590 3 1 to 9
(X, Y, Z, A, B, C,
U, V, W)
The "variables" for ID621.
Independent of a power failure.
621 0 1 to 9
(X, Y, Z, A, B, C,
U, V, W)
Start measurement of the dynamic
load.
630 0 1 to 175 You can explicitly determine whether
the SIK option given in IDX is set or
not.
1 = option is enabled
0 = option is not enabled
630 1 – It can be determined whether a
Feature Content Level (for upgrade
functions) is set, and which one.
–1 = no FCL is set
<No.> = FCL that is set
630 2 – Serial number of the SIK
–1 = no valid SIK in the system
Group
name
Group
number
ID....
System data
number
NR....
System data
index
IDX....
System datum