EasyManua.ls Logo

HEIDENHAIN iTNC 530 HSCI - PWM 9 encoder diagnostic kit

HEIDENHAIN iTNC 530 HSCI
1966 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
564 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP7493 Maximum deviation of the current tool orientation relative
to the tool axis when setting a reference point with M114
Input: 0.0000 to 30.0000 [degrees]
Default: 0.005
PLC
RUN
763
MP7494 Axes for which an exact stop is to occur after positioning
Format: %xxxxxxxxxxxxxxxxxx
Input: Bits 0 to 17 represent axes 1 to 18
0: No exact stop
1: Exact stop
PLC
RUN
MP7500
(is set via the
kinematics
table)
Reserved
MP7502 Functionality of M144/M145
Input: %xxx
Bit 0 -
0: M144/M145 not active
1: M144/M145 active
Bit 1 – M144/M145 in the automatic modes
0: M144/M145 active
1: M144 is activated automatically at the start of an NC
program. It can only be deactivated with M145
during an NC program.
Bit 2 – M144/M145 in the manual modes
0: M144/M145 not active
1: M144/M145 active
PLC
RUN
775
MP7503 Virtual tool axis – Reapproaching the contour and manual
traverse in the current tool-axis direction (FCL2 upgrade
function)
Input: 0: Inactive
1: Active
PLC
RUN
776
MP7506 Selection of kinematics at booting of the control
Input: 0 to 999
-1: Function inactive
PLC
RUN
720
MP Function and input Software
version and
behavior
Page

Table of Contents

Other manuals for HEIDENHAIN iTNC 530 HSCI

Related product manuals