564 HEIDENHAIN Technical Manual iTNC 530 HSCI
MP7493 Maximum deviation of the current tool orientation relative
to the tool axis when setting a reference point with M114
Input: 0.0000 to 30.0000 [degrees]
Default: 0.005
PLC
RUN
763
MP7494 Axes for which an exact stop is to occur after positioning
Format: %xxxxxxxxxxxxxxxxxx
Input: Bits 0 to 17 represent axes 1 to 18
0: No exact stop
1: Exact stop
PLC
RUN
–
MP7500
(is set via the
kinematics
table)
Reserved
MP7502 Functionality of M144/M145
Input: %xxx
Bit 0 -
0: M144/M145 not active
1: M144/M145 active
Bit 1 – M144/M145 in the automatic modes
0: M144/M145 active
1: M144 is activated automatically at the start of an NC
program. It can only be deactivated with M145
during an NC program.
Bit 2 – M144/M145 in the manual modes
0: M144/M145 not active
1: M144/M145 active
PLC
RUN
775
MP7503 Virtual tool axis – Reapproaching the contour and manual
traverse in the current tool-axis direction (FCL2 upgrade
function)
Input: 0: Inactive
1: Active
PLC
RUN
776
MP7506 Selection of kinematics at booting of the control
Input: 0 to 999
-1: Function inactive
PLC
RUN
720
MP Function and input Software
version and
behavior
Page